IQC

MFR firmly believes in the motto that:

“Good Materials result in Good Quality”

and hence has a exhaustive incoming quality plan to ensure that the raw materials under go the stringent incoming inspection and only those materials passing muster shall be used in the production of our high reliability products.

All our products conform to RoHS directive 2002/95/EC and REACH Norms.

A gist of the critical raw material inspection done at MFR is detailed below

Target

Target

Composition and purity by chemical analysis at external laboratory.

Rods

Dimensional checks: visual surface finish inspection under magnification weight evaluation of Alumina, Sodium and Potassium oxide contents at Central Glass Ceramic Research Institute, Kolkatta.

Rods
Caps

Caps

Dimensional checks, visual inspection of workmanship and plating under magnification. Performance evaluation with capping strength test.

Wire

Dimensional check, weight, plating inspection visual under magnification, Elongation, Solderability before and after phased ageing and steam bath exposure.

Wire
Epoxy, hardner thinner for resistor coating

Epoxy, hardner thinner for resistor coating

Pilot lot prepared from each lot and tested for visual appearance under magnification.

Long term life, climatic, temperature cycling resistance to solvent to ensure adherence to norms.

Belting tapes for belted resistors

Dimension check, Tensile Strength, Weight adhesion after heat exposure.

MFR utilises external laboratory facilities for evaluation of parameter which cannot be tested inhouse.

Belting tapes for belted resistors